ASTM B 231 Standard AAC All Aluminum Conductor

ASTM B 231 Standard AAC All Aluminum Conductor

Specifications:

    ASTM B231 is an ASTM International standard concentric stranded aluminum 1350 conductor.
    ASTM B 230 Aluminum Wire, 1350-H19 for Electrical Purposes
    ASTM B 231 Aluminum Conductors, Concentric-Lay-Stranded
    ASTM B 400 Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors

Quick Detail

Parameter Table

Quick Details :

AAC conductor is also known as an aluminium stranded conductor. The conductors have no insulation on their surface and are classified as bare conductors. It is manufactured from electrolytically refined Aluminium, with a minimum purity of 99.7%. They offer advantages such as corrosion resistance, light weight, low cost, and ease of handling and installation.

Applications :

AAC Conductor is used mainly in urban areas where the spacing is short and the supports are close. These regions have high requirements for the conductivity of conductors and low requirements for mechanical strength, and the performance of AAC conductors perfectly matches these requirements. All aluminium conductors are made up of one or more strands of aluminium wire depending on the end-user. Henan Jiapu Cable specializes in customizing cables to meet the various needs of customers. AAC is also used extensively in coastal regions because it has a high degree of corrosion resistance. In addition, it is also used in various locations such as transmission towers, low-voltage distribution lines, and building wiring.

Constructions :

Aluminum alloy 1350-H19 wires, concentrically stranded. The conductor consists of multiple layers of aluminum wires, with a central conductor surrounded by multiple layers of spiral-wound additional conductors.

AAC All Aluminium Conductors

Packing Materials :

Wooden drum,steel-wooden drum,steel drum.

ASTM B 231 Standard AAC Conductor Specifications

Code Name Size of Conductor Stranding and Wire Diameter Overall Diameter Max.D.C. Resistance at 20°C Code Name Size of Conductor Stranding and Wire Diameter Overall Diameter Max.D.C. Resistance at 20°C
 - AWG or MCM mm mm  Ω/km  - AWG or MCM mm mm  Ω/km
Peachbell 6 7/1.554 4.67 2.1692 Verbena 700 37/3.493 24.45 0.0813
Rose 4 7/1.961 5.89 1.3624 Nasturtium 715.5 61/2.75 24.76 0.0795
Lris 2 7/2.474 7.42 0.8577 Violet 715.5 37/3.533 24.74 0.0795
Pansey 1 7/2.776 8.33 0.6801 Cattail 750 61/2.817 25.35 0.0759
Poppy 1/0 7/3.119 9.36 0.539 Petunia 750 37/3.617 25.32 0.0759
Aster 2/0 7/3.503 10.51 0.4276 Lilac 795 61/2.90 26.11 0.0715
Phlox 3/0 7/3.932 11.8 0.339 Arbutus 795 37/3.724 26.06 0.0715
Oxlip 4/0 7/4.417 13.26 0.2688 Snapdragon 900 61/3.086 27.78 0.0632
Valerian 250 19/2.913 14.57 0.2275 Cockscomb 900 37/3.962 27.73 0.0632
Sneezewort 250 7/4.80 14.4 0.2275 Goldenrod 954 61/3.177 28.6 0.0596
Laurel 266.8 19/3.01 15.05 0.2133 Magnolia 954 37/4.079 28.55 0.0596
Daisy 266.8 7/4.96 14.9 0.2133 Camellia 1000 61/3.251 29.36 0.0569
Peony 300 19/3.193 15.97 0.1896 Hawkweed 1000 37/4.176 29.23 0.0569
Tulip 336.4 19/3.381 16.91 0.1691 Larkspur 1033.5 61/3.307 29.76 0.055
Daffodil 350 19/3.447 17.24 0.1625 Bluebell 1033.5 37/4.244 29.72 0.055
Canna 397.5 19/3.673 18.36 0.1431 Marigold 1113 61/3.432 30.89 0.0511
Goldentuft 450 19/3.909 19.55 0.1264 Hawthorn 1192.5 61/3.551 31.05 0.0477
Syringa 477 37/2.882 20.19 0.1193 Narcissus 1272 61/3.668 33.02 0.0477
Cosmos 477 19/4.023 20.12 0.1193 Columbine 1351.5 61/3.78 34.01 0.0421
Hyacinth 500 37/2.951 20.65 0.1138 Carnation 1431 61/3.89 35.03 0.0398
Zinnia 500 19/4.12 20.6 0.1138 Gladiolus 1510.5 61/4.00 35.09 0.0376
Dahlia 556.5 19/4.346 21.73 0.1022 Coreopsis 1590 61/4.099 36.51 0.03568
Mistletoe 556.5 37/3.114 21.79 0.1022 Jessamine 1750 61/4.302 38.72 0.0325
Meadowsweet 600 37/3.233 22.63 0.0948 Cowslip 2000 91/3.76 41.4 0.02866
Orchid 636 37/3.33 23.31 0.0894 Lupine 2500 91/4.21 46.3 0.023
Heuchera 650 37/3.366 23.56 0.0875 Trillium 3000 127/3.90 50.75 0.0192
Flag 700 61/2.72 24.48 0.0813 Bluebonnet 3500 127/4.21 54.8 0.01653