Medium Voltage Power Cable
-
IEC/BS Standard 18-30kV-XLPE Insulated MV Middle Voltage Power Cable
18/30kV XLPE-insulated medium-voltage (MV) power cables are specifically designed for distribution applications.
Cross-linked polyethylene provides the cables with excellent electrical insulation and thermal insulation. -
AS/NZS standard 19-33kV-XLPE Insulated MV Power Cable
19-33kV XLPE-insulated medium-voltage power cables are suitable for fixed installation in power supply networks within both indoor and outdoor environments. They may be installed in cable ducts, on cable trays, or directly buried underground.
-
IEC/BS Standard 19-33kV-XLPE Insulated MV Middle Voltage Power Cable
IEC/BS Standard 19/33kV XLPE-insulated MV power cables comply with International Electrotechnical Commission (IEC) and British Standards (BS) specifications.
IEC 60502-2: Specifies the construction, dimensions and tests for extruded insulated power cables up to 30 kV.
BS 6622: Applies to thermoset insulated armoured cables for voltages of 19/33 kV. -
IEC BS Standard 12-20kV-XLPE Insulated PVC sheathed MV Power Cable
Suitable for energy networks such as power stations. For installation in ducts, underground and outdoor.
There’s huge variations in construction, standards and the materials used – specifying the correct MV cable for a project is a matter of balancing the performance requirements, installation demands, and environmental challenges, and then ensuring cable, industry, and regulatory compliance. With the International Electrotechnical Commission (IEC) defining Medium Voltage cables as having a voltage rating of above 1kV up to 100kV that’s a broad voltage range to consider. It’s more common to think as we do in terms of 3.3kV to 35kV, before it becomes high voltage. We can support cable specifications in all voltages.
-
SANS Standard 3.8-6.6kV-XLPE Insulated MV Middle Voltage Power Cable
SANS Standard 3.8-6.6kV XLPE-insulated medium-voltage power cables are manufactured in accordance with South African National Standards.
Copper or Aluminium Conductors, single or 3 Core, Armoured or Unarmoured, bedded and served in PVC or non-halogenated material, Voltage Rating 6,6 up to 33kV, made to SANS or other National or International Standards -
SANS Standard 6.35-11kV-XLPE Insulated Middle Voltage Power Cable
11kV medium voltage electric power cable with copper conductors, semi-conductive conductor screen, XLPE insulation, semi-conductive insulation screen, copper tape metallic screen, PVC bedding, Aluminium wire armour (AWA) and PVC outer sheath. The cable is suitable for Voltage Rating 6,6 up to 33kV, made to SANS or other National or International Standards
-
SANS Standard 19-33kV-XLPE Insulated Middle Voltage Power Cable
SANS Standard 19-33kV XLPE-insulated medium-voltage power cables are manufactured and tested in accordance with South African National Standards.
The 33KV triple core power cable, is just a small part of our medium voltage cable range, it is suitable for power networks, underground, outdoors and installation in cable ducting.
Copper or Aluminium Conductors, single or 3 Core, Armoured or Unarmoured, bedded and served in PVC or non-halogenated material, Voltage Rating 6,6 up to 33kV, made to SANS or other National or International Standards -
ASTM Standard 15kV-XLPE Insulated MV Middle Voltage Power Cable
15kV-XLPE Insulated Middle Voltage Power Cable used for primary underground distribution in conduit systems suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 15kV or less and at conductor temperatures not to exceed 90°C for normal operation.
-
IEC/BS Standard 3.8-6.6kV-XLPE Insulated MV Middle Voltage Power Cable
IEC/BS 3.8/6.6kV XLPE-insulated medium-voltage (MV) power cables are standard cables specifically designed for distribution networks.
These cables are manufactured in accordance with International Electrotechnical Commission (IEC) and British Standards (BS) specifications.
3.8/6.6kV is a voltage rating more commonly associated with British standards, notably both BS6622 and BS7835 specifications, where applications can benefit from the mechanical protection provided by their aluminium wire or steel wire armour (depending on single core or three core configurations). Such cables would be well suited to fixed installations and providing power to heavy-duty static equipment as their rigid construction limits the bend radius. -
ASTM Standard 25kV-XLPE Insulated MV Middle Voltage Power Cable
25kV-XLPE Insulated Middle Voltage Power Cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication.
-
IEC/BS Standard 6.35-11kV-XLPE Insulated MV Middle Voltage Power Cable
IEC/BS Standard 6.35-11kV XLPE-insulated medium-voltage power cables are suitable for use in medium-voltage power distribution networks.
Electric cable with copper conductors, semi conductive conductor screen, XLPE insulation, semi conductive insulation screen, copper tape metallic screen of each core, PVC bedding, galvanized steel wires armour (SWA) and PVC outer sheath. For energy networks where mechanical stresses are expected. Suitable for underground installation or in ducts. -
ASTM Standard 35kV-XLPE Insulated MV Middle Voltage Power Cable
35kV-XLPE Insulated Middle Voltage Power Cables used for primary underground distribution in conduit systems suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 35kV or less and at conductor temperatures not to exceed 90°C for normal operation.