Medium Voltage Power Cable
-
SANS Standard 6.35-11kV-XLPE Insulated Middle Voltage Power Cable
11kV medium voltage electric power cable with copper conductors, semi-conductive conductor screen, XLPE insulation, semi-conductive insulation screen, copper tape metallic screen, PVC bedding, Aluminium wire armour (AWA) and PVC outer sheath. The cable is suitable for Voltage Rating 6,6 up to 33kV, made to SANS or other National or International Standards
-
SANS Standard 19-33kV-XLPE Insulated Middle Voltage Power Cable
SANS Standard 19-33kV XLPE-insulated medium-voltage power cables are manufactured and tested in accordance with South African National Standards.
The 33KV triple core power cable, is just a small part of our medium voltage cable range, it is suitable for power networks, underground, outdoors and installation in cable ducting.
Copper or Aluminium Conductors, single or 3 Core, Armoured or Unarmoured, bedded and served in PVC or non-halogenated material, Voltage Rating 6,6 up to 33kV, made to SANS or other National or International Standards -
ASTM Standard 15kV-XLPE Insulated MV Middle Voltage Power Cable
15kV-XLPE Insulated Middle Voltage Power Cable used for primary underground distribution in conduit systems suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 15kV or less and at conductor temperatures not to exceed 90°C for normal operation.
-
IEC/BS Standard 3.8-6.6kV-XLPE Insulated MV Middle Voltage Power Cable
IEC/BS 3.8/6.6kV XLPE-insulated medium-voltage (MV) power cables are standard cables specifically designed for distribution networks.
These cables are manufactured in accordance with International Electrotechnical Commission (IEC) and British Standards (BS) specifications.
3.8/6.6kV is a voltage rating more commonly associated with British standards, notably both BS6622 and BS7835 specifications, where applications can benefit from the mechanical protection provided by their aluminium wire or steel wire armour (depending on single core or three core configurations). Such cables would be well suited to fixed installations and providing power to heavy-duty static equipment as their rigid construction limits the bend radius. -
ASTM Standard 25kV-XLPE Insulated MV Middle Voltage Power Cable
25kV-XLPE Insulated Middle Voltage Power Cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication.
-
IEC/BS Standard 6.35-11kV-XLPE Insulated MV Middle Voltage Power Cable
IEC/BS Standard 6.35-11kV XLPE-insulated medium-voltage power cables are suitable for use in medium-voltage power distribution networks.
Electric cable with copper conductors, semi conductive conductor screen, XLPE insulation, semi conductive insulation screen, copper tape metallic screen of each core, PVC bedding, galvanized steel wires armour (SWA) and PVC outer sheath. For energy networks where mechanical stresses are expected. Suitable for underground installation or in ducts. -
ASTM Standard 35kV-XLPE Insulated MV Middle Voltage Power Cable
35kV-XLPE Insulated Middle Voltage Power Cables used for primary underground distribution in conduit systems suitable for use in wet or dry locations, direct burial, underground duct, and where exposed to sunlight. To be used at 35kV or less and at conductor temperatures not to exceed 90°C for normal operation.
-
IEC/BS Standard 6-10kV-XLPE Insulated MV Middle Voltage Power Cable
IEC/BS 6-10kV XLPE-insulated medium-voltage (MV) power cables comply with standards such as IEC 60502-2 for XLPE-insulated cables and BS 6622 for armoured cables.The conductors utilise XLPE to achieve excellent electrical insulation and thermal insulation.
-
AS/NZS standard 3.8-6.6kV-XLPE Insulated MV Power Cable
3.8-6.6kV XLPE-insulated medium-voltage power cables are suitable for distribution or secondary transmission networks, typically serving as the primary power supply for commercial, industrial, and urban residential networks. They are applicable to systems with high fault currents rated up to 10kA for 1 second. Structures with higher rated fault current capacities may be provided upon request.
-
IEC/BS Standard 8.7-15kV-XLPE Insulated MV Middle Voltage Power Cable
8.7/15kV XLPE-insulated medium-voltage (MV) power cables are specifically designed for power transmission and distribution networks.
This medium-voltage cable complies with the International Electrotechnical Commission (IEC) standards and British Standards (BS).
8.7/15kV, indicating suitability for systems with a maximum operating voltage of 15kV. 15kV is a voltage commonly specified for equipment cables, including robust Mining equipment cables, manufactured in accordance with IEC 60502-2, but is also associated with British standard armoured cables. Whilst mining cables may be sheathed in a robust Rubber to provide abrasion resistance, especially for trailing applications, the BS6622 and BS7835 standard cables are instead sheathed in PVC or LSZH materials, with mechanical protection provided from a layer of steel wire armouring. -
AS/NZS standard 6.35-11kV-XLPE Insulated MV Power Cable
6.35-11kV XLPE-insulated medium-voltage power cables are suitable for distribution or secondary transmission networks, typically serving as the primary power supply for commercial, industrial, and urban residential networks.
-
IEC/BS Standard 12.7-22kV-XLPE Insulated MV Middle Voltage Power Cable
Suitable for energy networks such as power stations. For installation in ducts, underground and outdoor.
The cables made to BS6622 and BS7835 are generally supplied with Copper conductors with Class 2 rigid stranding. Single core cables have aluminium wire armour (AWA) to prevent induced current in the armour, whilst the multicore cables have steel wire armour (SWA) providing the mechanical protection. These are round wires that provide over 90% coverage.