60227 IEC 52 RVV 300/300V Flexible Building Wire Light PVC Insulated PVC Sheath

60227 IEC 52 RVV 300/300V Flexible Building Wire Light PVC Insulated PVC Sheath

Specifications:

    60227 IEC 52(RVV) Light PVC Sheathed Flexible Cable For Fixing Wiring.
    It is also used in power installation, household electrical appliance, instrument,Telecommunications equipment, switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.

     

Quick Detail

Parameter Table

Product Tags

Quick Details:

Light PVC Insulated PVC Sheath RVV Flexible Building Wire for Internal Wiring

Applications:

60227 IEC 52 RVV 300/300V Flexible Building Wire is suitable for the household appliances, plant and machinery,wiring purpose and for manufacturing cords.The outer sheath provided here is special PVC,self-extinguishing and flame retardant. Bare copper, fine wire conductor, there’re 2 cores and 3 cores options for you. Rated voltages is 300/300V.

.

Technical Performance:

Rated Voltage (Uo/U):300/300V
Conductor temperature:Maximum conductor temperature in normal use: 70ºC
Installation temperature:Ambient temperature under installation shall not be below 0ºC
Minimum bending radius:
The bending radius of cable: (D-Diameter of cable)
D≤25mm------------------≥4D
D>25mm------------------≥6D


Construction :

Conductor:Number of conductors: 2,3 or other multi-core.
The conductors shall comply with the requirement given in IEC 60228 for class 5.
Assembly of cores:

Circular cord: the cores shall be twisted together.
Flat cord: the cores shall be laid parallel.
Insulation:PVC(Polyvinyl Chloride) Type PVC/D according to IEC
Sheath:PVC(Polyvinyl Chloride) Type PVC/ST5 according to IEC

Specifications:

60227 IEC 52 Standard

Contact Us:

Should any of these items be of interest to you, please let us know. We'll be satisfied to give you a quotation upon receipt of one's detailed specifications. We have our personal experienced R&D engineers to meet any of one's requirements, We appear forward to receiving your inquires soon and hope to have the opportunity to work together with you in the future. Welcome to check out our company.

60227 IEC 52 Light PVC Insulated PVC Sheath RVV Flexible Building Wire

Nominal Cross Sectional Area of Conductor Class of conductor Nominal Insulation Thickness Nominal Sheath Thickness Max.Overall Diameter Max.D.C.Resistance at 20 ℃ (Ω/km) Min.Insulation Resistance at 70 ℃
(mm²) / (mm) (mm) (mm) Plain Metal-coated (Ω/km)
2×0.5 5 0.5 0.6 5.9 39 39 0.012
2×0.5 5 0.5 0.6 3.7×5.9 24 39 0.012
2×0.75 5 0.5 0.6 6.3 46 26 0.01
2×0.75 5 0.5 0.6 3.8×6.3 31 26 0.01
3×0.5 5 0.5 0.6 6.3 49 19.5 0.012
3×0.75 5 0.5 0.6 6.7 60 19.5 0.01