IEC BS Standard 12-20kV-XLPE Insulated PVC sheathed MV Power Cable

IEC BS Standard 12-20kV-XLPE Insulated PVC sheathed MV Power Cable

Specifications:

    Suitable for energy networks such as power stations. For installation in ducts, underground and outdoor.

    There’s huge variations in construction, standards and the materials used – specifying the correct MV cable for a project is a matter of balancing the performance requirements, installation demands, and environmental challenges, and then ensuring cable, industry, and regulatory compliance. With the International Electrotechnical Commission (IEC) defining Medium Voltage cables as having a voltage rating of above 1kV up to 100kV that’s a broad voltage range to consider. It’s more common to think as we do in terms of 3.3kV to 35kV, before it becomes high voltage. We can support cable specifications in all voltages.

     

Quick Detail

Parameter Table

Product Tags

Application :

Suitable for energy networks such as power stations. For installation in ducts, underground and outdoor. Please note: Red outer sheath can be prone to fading when exposed to UV rays.

Standards:

Flame propagation to BS EN60332
BS6622
IEC 60502

Characteristics :

Conductor: stranded plain annealed circular compacted copper conductors or aluminium conductor
Insulation: cross link polyethylene (XLPE)
Metallic Screen: individual or overall copper tape screen
Separator: copper tape with 10% overlap
Bedding: polyvinyl chloride (PVC)
Armouring: Steel Wire Armour (SWA), Steel Tape Armour (STA), Aluminium Wire Armour (AWA), Aluminium Tape Armour (ATA)
Sheath: PVC outer sheath
Sheath colour: Red or Black

Electrical data:

Maximum conductor operating temperature: 90°C
Maximum screen operating temperature: 80°C
Maximum conductor temperature during S.C: 250°C
Laying conditions at trefoil formation are as below:
Soil thermal resistivity: 120˚C. Cm/Watt
Burial depth: 0.5m
Ground temperature: 15°C
Air temperature: 25°C
Frequency: 50Hz

Single core 12/20 kV

Nominal area conductor Conductor diameter Insulation thickness Nominal overall diameter Maximum overall diameter Approximate cable weight kg/km Minimum bending radius
mm² mm mm mm mm Cu Al mm
1x 25 6.0 5.5 26.0 27.0 892 737 380
1x 35 7.0 5.5 27.1 28.1 1021 804 390
1x 50 8.2 5.5 28.5 29.5 1216 902 410
1x 70 9.9 5.5 30.2 31.2 1464 1024 440
1x 95 11.5 5.5 32.0 33.0 1769 1171 460
1×120 12.9 5.5 33.4 34.4 2052 1297 480
1×150 14.2 5.5 34.9 35.9 2391 1447 500
1×185 16.2 5.5 37.1 38.1 2805 1640 530
1×240 18.2 5.5 39.1 40.1 3381 1870 560
1×300 21.2 5.5 42.3 43.3 4065 2176 600
1×400 23.4 5.5 44.7 45.7 5077 2553 640
1×500 27.3 5.5 48.8 49.8 6166 3017 700
1×630 30.5 5.5 52.4 53.4 7526 3559 750

Three cores 12/20 kV

Nominal area conductor Conductor diameter Insulation thickness Nominal overall diameter Maximum overall diameter Approximate cable weight kg/km Minimum bending radius
mm² mm mm mm mm Cu Al mm
3x 25 6.0 5.5 52.4 53.4 3611 3146 750
3x 35 7.0 5.5 54.5 55.5 4083 3432 770
3x 50 8.2 5.5 57.4 58.4 4771 3826 810
3x 70 9.9 5.5 61.2 62.2 5714 4392 870
3x 95 11.5 5.5 65.0 66.0 6810 5015 920
3×120 12.9 5.5 68.2 69.2 7847 5580 970
3×150 14.2 5.5 71.2 72.2 9000 6166 1010
3×185 16.2 5.5 75.6 76.6 10481 6986 1070
3×240 18.2 5.5 80.5 82.0 12700 8200 1140

Armoured three cores 12/20 kV

Nominal area conductor Conductor diameter Insulation thickness Nominal overall diameter Maximum overall diameter Approximate cable weight kg/km Minimum bending radius
mm² mm mm mm mm Cu Al mm
3x 25 6.0 5.5 57.5 58.5 5045 4580 820
3x 35 7.0 5.5 59.8 60.8 5630 4979 850
3x 50 8.2 5.5 62.7 63.7 6381 5436 890
3x 70 9.9 5.5 66.5 67.5 7450 6128 940
3x 95 11.5 5.5 70.1 71.1 8614 6820 990
3×120 12.9 5.5 73.5 74.5 9780 7513 1040
3×150 14.2 5.5 76.3 77.3 10962 8128 1080
3×185 16.2 5.5 80.9 81.9 12611 9116 1140
3×240 18.2 5.5 85.5 86.5 14792 10258 1210